Mar 08, 2024 Leave a message

What Are The Methods For Finding The Broken Core Of Wire And Cable?

Cable in the case of use may produce some failures, such as cable penetration, cable conductor damage, broken core and other failures. The conductor of the flame-retardant cable is small in the total area of the cross section, and it is likely to be torn off during the whole process of making the cable. The following basic knowledge content for you to understand is - cable cable cable broken core search method is what?

Some cable factories in this regard usually use the comparative analysis of capacitors to search for the approximate part of the disconnect. The continuous plugging method is used to reasonably break the cable, and the rate of such methods is very low. It usually takes about an hour and a half to search for a break point. This method is almost unlikely to find a broken core for flame-retardant cables that have already been shielded, armoured cables, and bushing processes, and poor practice will continue to damage flame-retardant cables. Such methods are often no longer needed.

Two: Capacitor method and magnetic induction method fusion: This type of method is applied to the broken core of the cable core, which stipulates that the cable core is not covered by a metal material layer and there is no extrusion coating. In the case of search, the capacitor is first used to find the approximate part of the cable disconnect, and then the induction voltage method is used to search the disconnect point. This type of method is very simple and convenient, and it is also a way of application at this stage. Inductive voltage method is to connect 650V AC current at one end of the broken core of the cable, the other end and its core grounding device, and then use a detection pen that can send light signals to detect, when the test is when the magnetic induction pen slips from the broken core, the data signal will change, so that you can search for the cable break point.

Three: DC power supply and bridge method is closely combined This way is used for cable or cable core that has been covered with a metal material layer. The next way is to first use the DC power supply to burn and penetrate the insulation layer at the broken core of the flame retardant cable, and then accurately locate the fault point using the bridge fault detector, which is also a commonly used way. There are the following ways to prevent cable fire:

1, ensure the construction quality, especially the quality of the cable head must be strictly in line with the requirements.

2, strengthen cable operation monitoring to prevent cable overload operation.

3. Carry out cable testing on time, and properly handle abnormalities when found.

4, the cable trench to maintain dry and impetuous, to avoid cable moisture, resulting in insulation layer reduction, resulting in short circuit fault.

5. Clean the dust accumulated on the cable on time to avoid the fire caused by the dust.

6, strengthen the cable circuit switch and maintenance of regular check maintenance, to ensure that its posture is reliable.

7, the cable laying should always maintain sufficient spacing with the heat pipe, the control cable is not less than 0.5 meters; The driving power cable is not less than l meters. The control cable and the driving cable should be slotted, stratified and separated, and cannot be placed with solid layer coincidence. For the position that does not meet the requirements, the cable should adopt flame retardant and heat insulation countermeasures.

 